LOADMISER™ Energy Divider Controller

Model #D-LM

IDEAL FOR COST AND ENERGY SAVINGS, OR WHEN SYSTEM CAPACITY IS LIMITED SUCH AS THE ADDITION OF A HOT TUB, ELECTRIC VEHICLE CHARGER ETC. TO EXISTING SERVICE.

  • EEMAC 3R enclosure

  • Specifically designed as a load saving device, to be used where non-essential

    load is connected to an essential load circuit

  • Load saver cuts off power to the non-essential circuit only. Reducing load saves

    service upgrades

  • Factory adjustable 5 to 50 Amp of the circuit upstream rating

  • Easy to install for new and existing installations, simply connect in series of the

    existing load

  • Optional time of day clock prevents non-essential load from operation on/off

    hour, increasing energy savings and allowing non-essential load to operate

    on/off time energy availability

  • Sensing has adjustable 5 to 50 second time delay action to prevent rapid load

    cycling. Sensing is on only L1. To avoid nuisance tripping if loads are

    unbalanced add second phase current sensor option

  • White powder coat finish

  • CSA certified assembly

Options

  • Large capacity control to 600A, 600V

  • Dual line sensing - recommended when unbalanced loads could be

    encountered

  • Time clock for interval operation of load contactor eg. time of day

  • Extra large body sized 18" x 14" x 5"

  • Loadside branch circuit breaker on essential circuit or non essential circuit

  • Remote control output

  • Split CT design

Note

  • Refer to CEC Rule #’s 8-106 (4), (10) and (11), 8-500, and 12-3022 (4)

Read more by downloading the Catalogue PDF


Amy Broere